• AT-868

    Aplicação

    As suas características únicas, particularmente baixo custo, tamanho pequeno, alto desempenho, display local, tornam a escolha ideal para automação industrial, processamento de controle, redes de medidor de fluxo, compondo multi-canal, medidor de fluxo de alta precisão.

    Caracteristicas Técnicas

     

    1 canal, com 1 par transdutores e sistema de fixação

    Pipe Sizes

    • Clamp-on transducers: 0.5 to 300 in. (12.7 mm to 7.6m)

      and larger

    • Wetted transducers: 1 in to 200 in (25.4 mm to 5 m)

      and larger

      Pipe-Wall Thickness&nbsp, Up to 3 in (76.2 mm)

      Pipe Materials

      All metals and most plastics. Consult GE for concrete,

      composite materials, and highly corroded or lined pipes.

      Clamp-On Flow Accuracy (Velocity)

    • Pipe ID&gt,6 in (150 mm): ±1% to 2% of reading typical

    • Pipe ID&lt,6 in (150 mm): ±2% to 5% of reading typical

      Wetted Flow Accuracy (Velocity) ±1% of reading typical

      Accuracy depends on pipe size and whether&nbsp, measurement is one-path or two-path. Accuracy to ±0.5% of reading may be achievable with process calibration.

      Repeatability ±0.1% to 0.3% of reading

      Range (Bidirectional) –40 to 40 ft/s (–12.2 to 12.2 m/s)

      Rangeability (Overall) 400:1

      Digital Interfaces

    • Standard: RS232

    • Optional: RS485 (multiuser)

      European Compliance System complies with EMC Directive 89/336/EEC, 73/23/EEC LVD (Installation Category II, Pollution Degree

      2) and transducers comply with PED 97/23/EC for DN&lt,25

      Clamp-On Ultrasonic&nbsp, Flow Transducers

      Temperature Ranges

    • Standard: –40°F to 300°F (–40°C to 150°C)

    • Optional: –40°F to 210°F (–40°C to 230°C)

      Mountings&nbsp, Stainless steel chain or strap, welded or magnetic

      clamping fixtures

      Area Classifications

    • Standard: General purpose

    • Optional: Weatherproof Type 4/IP65

    • Optional: Submersible IP67/68

      Wetted Ultrasonic Flow Transducers

      Temperature Range&nbsp, –40°F to 212°F (–40°C to 100°C)

      Pressure Range&nbsp, 0 to 3000 psig (1 to 207 bar)

      Specifications assume a fully developed flow profile (typically 10 diameters upstream and 5 diameters downstream of straight pipe run) and flow velocity greater than 1 ft/s (0.3 m/s).

      Measurement Parameters

      Volumetric flow, totalized flow and flow velocity

      Electronics

      Flow Measurement Patented Correlation Transit-Time mode Enclosure&nbsp, Epoxy-coated aluminum weatherproof Type 4X/IP66

      Dimensions&nbsp, Standard: Weight 2 lb (0.9 kg), size (h x w x d) 7.25 in x 5.9 in x 3.5 in (184 mm x 150 mm x 89 mm)

      Channels

    • Standard: One channel

    • Optional: Two channels (for two pipes or two-path

      averaging) &nbsp,Display&nbsp, 2-line x 16 character backlit LCD display, configurable to display up to four measurement parameters in sequence Keypad&nbsp, Six-button internal keypad Power Supplies

    • Standard: 85 to 265 VAC, 50/60 Hz

    • Optional: 12 to 28 VDC, ± 5%

      Power Consumption 20W maximum

      Operating Temperature 14°F to 131°F (–10°C to 55°C)

      Storage Temperature –40°F to 158°F (–40°C to 70°C)

      Standard Inputs/Outputs

    • One 0/4 to 20 mA isolated output per channel, 600 S maximum load

    • One frequency/pulse rate/totalizer output per channel,

      optically isolated, 3A maximum, 100 VDC maximum, 1W maximum, from 0.1 to 10 kHz

      Materials

    • Standard: Stainless steel

    • Optional (for Pan-Adapta® Plugs):

      Titanium, Hastelloy® alloy, Monel® alloy, duplex,

      CPVC, PVDF and others Pan-Adapta plugs allow installation and removal of wetted transducers without interrupting the process or emptying the pipe.

      Process Connections

    • Standard: 1 in or 3/8 in NPTM

    • Optional: RF flanged, socket weld, fuse bond and

      Others&nbsp, Mountings Flanged flowcell, hot tap or cold tap

      Area Classifications

    • Standard: General purpose

    • Optional: Weatherproof Type 4/IP65 submersible

      Transducer Cables

    • Standard: One pair of coaxial cables, type RG62 AU, or

      as specified for transducer type

    • Optional: Lengths up to 1000 ft (330 m) maximum

      Additional Options PanaView™ PC-Interface Software

      The AquaTrans AT868 communicates with a PC through

      a serial interface and Windows® operating systems.

      Consult the manual for details on sites, logs, and other

      operations with a PC.

    AT-868